It has long been the position of the American Academy of Underwater Sciences that the ultimate responsibility for safety rests with the individual diver. .
The time has come to encourage divers to slow their ascents,
1. Buoyancy compensation is a significant problem in the control of ascents.
2. Training in, and understanding of, proper ascent techniques is fundamental to safe diving practice.
3. Before certification, the diver is to demonstrate proper buoyancy, weighing and a controlled ascent, including a 'hovering' stop.
4. Divers shall periodically review proper ascent techniques to maintain proficiency.
5. Ascent rates shall not exceed 60 feet of sea water per minute.
6. A stop of the 10 to 30 feet of sea water zone for three-to-five minutes is recommended on every dive.
7. When using a dive computer or tables, non-emergency ascents are to be at the rate specified for the system being used.
8. Each diver shall have instruments to monitor ascent rates.
9. Divers using dry suits shall have training in their use.
10. Dry suits shall have hands-free exhaust valves.
11. BC's shall have a reliable rapid exhaust valve which can be operated in a horizontal swimming position.
12. A buoyancy compensator is required with dry suit use for ascent control and emergency flotation.
13. Breathing 100 percent oxygen above water is preferred to in-water air procedures for omitted decompression